Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800–1000

800–1000

800–1000

800–1000

2nd. Chamber Temperature

1000-1200

1000-1200

1000-1200

1000-1200

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm


The unit should have the following features:
•   Automatic feeding
•   Automatic ash / leftovers removal
•   Flue gas filtration system.
The technical & financial offer should include installation & testing and staff training.
•   Low running and maintenance costs
•   Automatic and simple to operate control panel
•   Incineration temperatures in excess of 850°C
•   5mm steel casing and fully insulate
Dense refractory concrete lining rated to 1600°C Solid hearth to allow maximum burnout
•   Large top opening lid for easy loading
Wide door for ash removal Stainless steel flue as standard Afterburner fitted as standard
•   12 month or 400 / 1000 hours warranty. DEFRA approved
Easy on-site installation Optional heat recovery system Optional stainless steel casing
•   Optional Gas Cleaning System

High quality monolith refractory lining rated up to
1600ºC. Monolith design structural stability, optimal heat retention (without losses on joints), and makes maintenance extremely simple and cost efficient. High quality insulation coating. 20 mm insulation Layer. Excellent heat
retention in the primary chamber, minimizing energy losses (increased
efficiency), while protecting outside steel structure providing longer
equipment life-time and safer environment for the operators.


Steel structure made of high quality durable steel. Compact design that allows simple installation and transport of the incinerators.
Treated with special HT paint. Heat resistant
Internal shape designed for optimal heat distribution avoiding cold spots and
providing liquid retention.
Ash removal door for easy and efficient ash removal.

Diesel oil operated with improved energy efficiency Lower emissions of nitrous oxides with wide working field (100 – 300 kW) adjustable for different applications.
Constant ventilation with adjustable air flow to provide
optimal combustion conditions and efficient gradual cooling of the system
Heat resistant 5mm steel, Stainless steel stack, 12cm of refractory lining – steel reinforced.
The offer should be itemized. IMPORTANT INFORMATION:
1.   Emission standards : ( EU )
2.   Waste type: Hazardous Medical Waste
3.   Approximate moisture content: max. 30%
4.   Glass content: max. 15% 5. Building Roof Height: 8 meters
5.   Height of chimney above roof (required): at least 3 meters
6.   Fuel to be used : No. 2 ( diesel ) ( Fuel specifications attached )
7.   Power: 380 V, 3 phase
8.   Manual English
Electrical requirements
220v -240v, single phase 50-60Hz – 13-16 amp
Control panel
Weather resistant, IP65 rated
User friendly, simple to operate plug and play control panel
Controls primary and secondary burner
Thermostatic device (for increased fuel efficiency) HQ durable temperature probe
Fully automatic control of burners with temperature monitoring display.
Fuel Tank  650 Liters &   piping  system to the incinerator
Service Parts for 1 year service
Prefabricated Shelter to protect the incinerator from weather  Sun & Rain with lockable doors

 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

 

2020-10-29

Post Author: admin